top of page

Sysmex CS-2000i/2100i

Sysmex Corporation. Japan
DESIGNED FOR VERSATILITY AND SUPERIORITY IN THE LABORATORY

The CS series analyzers are capable of simultaneously performing clotting, chromogenic, immunoturbidimetric, and aggregation assays.

Multi-wavelength technology, featuring an optical system that automatically adapts based on sample properties, enables highly accurate results—even when working with "difficult" samples.

The optical system comprises 10 independent analytical channels, enabling the CS-2500 analyzer to perform tests using all supported methodologies simultaneously at no fewer than five wavelengths.

Process automation

Thanks to the ability to work with primary tubes, samples can be placed into the analyzer immediately after centrifugation, without any additional handling.

Reagents, samples, and cuvettes are loaded during operation, ensuring continuous testing regardless of the workload.

The capacity to load 500 cuvettes on board ensures long-term instrument operation without operator intervention.

When upper and lower limits for re-analysis are set, the system automatically performs a re-analysis—using new dilutions, if necessary.

Automated coagulometer with sample quality pre-assessment and platelet analysis functions

Automated hemostasis analyzer

Assessment of all components of the hemostasis system, including the platelet component (a total of over 60 different tests)

An integrated aggregometer allows for the assessment of platelet function.

Throughput of up to 180 tests per hour

Integrated automated system for quality assessment of the pre-analytical phase

Function for adapting the analyzer's optical system to the properties of a specific sample

Reagent consumption optimization function

​Preanalytical and analytical control

Determination of the correctness of the blood-to-anticoagulant ratio, with the option (at the user's discretion) to accept or reject the sample for further analysis.

The optical system allows for the assessment of the level of hemolysis, icterus, and lipemia in a sample, with subsequent flagging of results that do not meet user-defined quality criteria.

image.png

The cap-piercing function (CS-2100) eliminates direct contact with biological material, significantly reducing the risk of infection via airborne transmission.

Reagent racks are placed on a dual, rotating, temperature-controlled tray with 40 positions.

The vials are slightly tilted to reduce dead volume and increase the number of tests per vial, which enhances the economic efficiency of operating the analyzer.

One of the sections of each reagent rack allows for the mixing of reagents.

CHARACTERISTICS

Measurement principle

Clotting method

Chromogenic substrate method

Immunoturbidimetry

Reagents

Parameters under investigation

​Wavelengths

40 positions, with thermostat or cooling function, as well as stirring

Over 60 different tests: PT, aPTT, fibrinogen, extrinsic pathway factors (II, V, VII, X), intrinsic pathway factors (VIII, IX, XI, XII), Factor XIII (chromogenic), AT-III, α2-antiplasmin, plasminogen, Protein S, fibrin degradation products, von Willebrand factor, D-dimer, platelet aggregation analysis using various inducers, etc.

Multi-wavelength system for simultaneous sample scanning at 5 wavelengths: 340, 405, 575, 660, and 800 nm.

Productivity

PT: up to 180 tests per hour

PT + APTT: up to 180 tests per hour

PT + APTT + optical fibrinogen: up to 180 tests per hour

PT + APTT + optical fibrinogen + antithrombin + D-dimer: up to 95 tests per hour

Measurement channels

10 analytical channels. 4 of these feature a stirring function for aggregometry, enabling the simultaneous use of a full range of analytical methods: clotting, chromogenic, immunoturbidimetric, and aggregation assays.

Number of samples

Up to 50 samples on board simultaneously, in primary or secondary tubes

5 separate positions for urgent samples

Sample size

From 5 µl. Aspiration of samples and reagents using a sampling probe with automatic liquid level detection in the tube.

​Cuvettes

Quality Control

Dimensions

Simultaneous loading of 500 cuvettes with automatic feed

Levey-Jennings 1200 points × 750 files, 40 parameters

Main unit: 775 x 675 x 865 / 100 kg

Pneumatic unit: 280 x 400 x 355 mm / 17 kg