top of page

Sysmex CA-660

Sysmex Corporation. Japan
DESIGNED FOR VERSATILITY AND EXCELLENCE IN THE LABORATORY
image.png

In addition to standard coagulogram tests, the analyzer allows for an in-depth assessment of each stage of plasma hemostasis, as well as the diagnosis of thrombophilia and the causes of hemorrhagic disorders.

The diagnostic and analytical capabilities of the CA-660 analyzer allow it to be used as a primary analyzer (for workloads of up to 50 coagulograms per shift) or as a backup analyzer.

A special factor measurement mode, featuring automatic control of the parallelism between the sample and the calibrator, ensures high accuracy of results and ease of operation.

image.png

Hemostasis analyzer

Automatic coagulometer with high analytical reliability of results

Uses clotting, chromogenic, and immunoturbidimetric assessment methods

Color touchscreen LCD screen and built-in barcode scanner

Throughput of up to 60 tests/hour with STAT testing capability

Виділений інтерфейс для онлайн-сервісів Sysmex

image.png
Accuracy and clinical effectiveness

Using a barcode scanner, you can quickly and easily register information about reagents, standards, and controls.

10-sample autosampler with continuous sample loading

The built-in reagent cooling system enhances their stability.

The procedure for configuring and updating the analyzer, as well as for backing up and restoring data and user settings, is quite simplified.

LIS connectivity

CHARACTERISTICS

Measurement principle

Reagents

Продуктивність

Measuring channels

Кількість зразків

Sample size

Analysis Mode

Memory

Cuvettes

Quality Control

Dimensions

Clotting-based: PT, INR, aPTT, Fibrinogen, coagulation factors, thrombophilia diagnostic tests, etc.

Chromogenic: Antithrombin, Protein C, Protein S, plasminogen, heparin, etc.

Immunological: D-dimers, von Willebrand factor, etc.

13 positions for reagents

60 tests per hour (PT)

48 tests per hour (PT, APTT, Fibrinogen)

40 tests per hour (PT, APTT, Fibrinogen, AT-III)

32 tests per hour (PT, APTT, Fibrinogen, D-Dimer)

6 channels

10 samples in primary or secondary tubes

Dedicated position for STAT samples

Automatic sample loading

Automatic pre-dilution system for samples and calibrators

50 µL (PT, APTT, TT)

10 µL (Fbg)

5 µL (clotting factor assay)

14 open protocols for test programming; the CA-660 is capable of measuring up to five parameters simultaneously.

Automatic dilution function for the accurate measurement of abnormal fibrinogen levels.

Up to 600 samples / max. 3,000 tests

Disposable replacement cuvettes

60 cuvettes on board simultaneously

x-bar (mean) / L-J (Levey-Jennings) control

6 files, 180 data points, 14 parameters

Dimensions: 566 x 490 x 490 mm. Weight: 42 kg