Sysmex CN-3000/6000
Sysmex Corporation. Japan

DESIGNED FOR VERSATILITY AND EXCELLENCE IN THE LABORATORY
The smallest footprint, highest throughput, and most comprehensive test menu on a single analyzer—ranging from routine to specialized tests (e.g., DOAC and platelet function assays/aggregatometry).
The minimum plasma volume required for analysis has been reduced by 65% through the implementation of a new, improved sample dosing system.
Автономні прилади, що окремо стоять, у стандартній комплектації
Enables the use of various analytical methods—such as the analysis of inhibitory activity via cross-mixing tests and Reaction Curve Analysis (CWA) for detecting abnormal clot formation kinetics—which may be observed in patients with coagulopathies.
Automated coagulometer with capabilities for preliminary sample quality assessment and platelet function analysis
Measuring principles: clotting, chromogenic, immunochemical and aggregation
38 positions for reagents (with cooling capability to 4–12°C) and 6 positions for buffers (room temperature)
A modular system that scales with your needs
The CN-3000 and CN-6000 can be flexibly configured to meet the individual needs of laboratory automation.
Test volume forecasting function; automated dilution of platelet aggregation agonists
Combines routine and specialized tests—including aggregometry tests—in a single analyzer.
Control of pre-analytical and analytical phases
Automated control of the pre-analytical phase: preliminary screening of samples for hemolysis, icterus, and chyle (HIL detector), as well as assessment of the correct anticoagulant-to-blood ratio (sample volume detector).
Multi-wavelength technology that automatically adapts the analyzer’s optical system based on sample properties (analyte concentration, presence of hemolysis, turbidity, or icterus), ensuring highly accurate results even when processing complex samples.

Process automation
Capability to work with primary tubes; samples can be placed into the analyzer immediately after centrifugation, without requiring additional handling.
The cap-piercing function allows for the use of primary tubes and eliminates direct contact with biological material.
Full automation of the sample dilution system, both for determining factor or inhibitory activity in plasma and for constructing calibration curves.
Автоматична система попереднього розведення реагентів, виходячи з пр огнозованої оцінки кількості тестів
Reagents, samples, and cuvettes are loaded during operation, ensuring continuous testing regardless of the workload.
CHARACTERISTICS
Measurement principle
Reagents
Parameters under investigation
Wavelengths
Productivity
Measuring channels
Number of samples
Calibration
Memory
Cuvettes
Quality Control
Dimensions
The service life of the lid-piercing system has been increased fourfold compared to previous models.
The optical system uses an LED, which has increased the light source's lifespan to 36,000 hours.
Reagent vials are positioned at an angle in the rack, which reduces dead volume and increases the number of tests that can be performed with each vial.

Measurement principles: clotting, chromogenic, immunochemical, and aggregation
38 positions for reagents (with cooling capability to 4–12°C) and 6 positions for buffers (room temperature)
Clotting assays: PT, aPTT, Fibrinogen, Batroxobin (Reptilase) time, TT, factors of the extrinsic and intrinsic pathways (II, V, VII, X, VIII, IX, XI, XII), Protein S, Protein C, Factor V Leiden, Lupus Anticoagulant (LA), ProC Global, Rivaroxaban, Apixaban, Edoxaban, Dabigatran
Chromogenic assays: Antithrombin III (AT-III), Plasminogen (PLG), Alpha-2-antiplasmin (α2-AP), Protein C (PC), FVIII, FXIII, PAI levels and activity, Heparin, C1-inhibitor, etc. Immunological assays: D-dimer, von Willebrand factor concentration and activity (vWF:Ag, vWF:Ac), etc.
Aggregometry: assessment of platelet function using various inducers (ADP, arachidonic acid, collagen, ristocetin), evaluation of the efficacy of antiplatelet therapy (aspirin, clopidogrel), and ristocetin-based von Willebrand factor activity.
Multi-wavelength system for simultaneous sample scanning at 5 wavelengths (340, 405, 575, 660, and 800 nm)
CN-3000:
PT: 225 tests/hour, PT+APTT: 215 tests/hour
CN-6000:
PT: 450 tests/hour
PT+APTT: tests/hour
CN-3000 – 13 analytical channels (4 with aggregometry capability)
CN-6000 – 26 analytical channels (8 with aggregometry capability)
Simultaneous loading of 30 samples as standard; capacity expandable to 120 samples using the SA-90 auto-loader system (optional)
Cap-piercing capability; positions for emergency (STAT) samples
Simultaneous availability of calibration curves (2–12 points) for 250 methods
Up to 10,000 samples
Simultaneous loading of up to 1,200 cuvettes, with the capability for continuous reloading.
Automated quality control program. X-bar control, Levey-Jennings, and Westgard rules monitoring. Up to 40 control files, with 1,200 data points for each.
595 x 1350 x 906 cm, 230 kg (PU 17 compressor included; computer and monitor not included).