top of page

Sysmex UC-1000

Sysmex Corporation. Japan
DESIGNED FOR VERSATILITY AND EXCELLENCE IN THE LABORATORY

The analyzer is effective for routine urinalysis in laboratories with a low workload, and it can also facilitate point-of-care testing (POCT) in a physician's office or an emergency department setting.

The UC-1000 can serve as a backup unit in high-volume laboratories that utilize high-throughput automated systems from the UN series (UC-3500 and UF-4000/5000). The UC-1000 can be integrated into the comprehensive UN urinalysis system via specialized U-WAM software.

The results of an analysis using MEDITAPE diagnostic strips can be evaluated either by using the UC-1000 analyzer or visually, based on a specific scale provided on each package of strips.

Semi-automated urine analyzer

Reflectance photometry combined with CMOS sensor technology for expanding the diagnostic capabilities of urine test strip analysis

Results in less than a minute, with continuous loading of test strips every 8 seconds.

Expanded diagnostic capabilities in the assessment of hematuria and proteinuria: erythrocyturia/hemoglobinuria, microalbumin, creatinine

Small dimensions and low weight

Accuracy and clinical effectiveness

The technology implemented in the UC-1000 eliminates the impact of factors such as lighting conditions and uneven coloration of the test zone on analysis results, significantly increasing the confidence of both physicians and patients in the findings.

The UC-1000 utilizes the principle of multi-wavelength reflectance photometry with an image-saving function. The device scans each test zone on the strip, capturing an image that is subsequently analyzed automatically.

A two-level control material, certified for all parameters measured by the UC-1000, will ensure effective internal quality control for urinalysis.

MEDITAPE UC-10S, MEDITAPE UC-12S diagnostic strips are characterized by high stability to interfering factors, including ascorbic acid, which is present in urine, which allows obtaining an analytically reliable result of a urine test

The image of each analyzed strip is saved and can be used at any time—for example, in the event of an error verification.

CHARACTERISTICS

Measurement principle

CBC+DIFF mode parameters (standard for XN-10/20)

Productivity

Quality Control

Dimensions

An advanced reflectance photometry method combined with CMOS sensor technology

MEDITAPE UC-10S: pH (pH), glucose (GLU), protein (PRO), erythrocytes/hemoglobin (BLD), urobilinogen (URO), ketones (KET), bilirubin (BIL), nitrites (NIT), leukocytes (LEU), specific gravity (SG)

MEDITAPE UC-12S: pH (pH), glucose (GLU), protein (PRO), erythrocytes/hemoglobin (BLD), urobilinogen (URO), ketones (KET), bilirubin (BIL), nitrites (NIT), leukocytes (LEU), specific gravity (SG), creatinine (CRE), albumin (ALB), protein/creatinine (PRO/CRE ratio), albumin/creatinine (ALB/CRE ratio)

Up to 480 samples per hour

Two-level control material UC control (H/L) 2 x 3 x 10 ml

​315 x 135 x 215 mm / 2.6 kg

bottom of page